GrassMaster history
The first ever full-size GrassMaster field was installed at RKVV Wilhelmina in Den Bosch in the Netherlands, and clubs like Huddersfield, West Ham United, Feyenoord FC, Real Madrid, AS Monaco, Nantes FC and Bayer Leverkusen followed in the years between 1996 and 2004. However, it was the use of the surface at the 2004 Athens Olympics and the EURO 2004 in Portugal that made GrassMaster shoot to prominence. During the 2005/2006 season, many clubs in the English Premier League played on a GrassMaster surface, with Wembley Stadium following in 2010. GrassMaster saved the day for the Mbombela and Polokwane Stadiums in 2010 when both FIFA World Cup venues had their field reinforced shortly before the start of the 2010 World Cup tournament.GrassMaster concept
A GrassMaster pitch has approximately 20 million polypropylene fibres of 20 cm length injected 18 cm deep into the soil in a 2×2 cm grid. The final result will be a surface made up of 3% synthetic turf. The synthetic turf fibres are slightly shorter than the natural grass and will make the surface look green, even when all the grass is gone. It also gives stability to the soil and prevents sods being taken out when players slide over the surface.GrassMaster construction
GrassMaster requires a very sandy soil without soil life or organic matter, similar to those used for installing synthetic turf. The yarn can be injected before or after seeding of the grass or onto the grass sods. The grass roots will intertwine with the fibres. The sandy nature of the soil and the contribution the synthetic turf fibres make in flushing water down along the fibres is why some people complain that the surface quickly dries out. Grass clippings always have to be removed from the grass, as this stimulates soil life as well as the presence of felt in between the grass blades. Felt will push the synthetic turf fibres down, which will affect the performance of the GrassMaster surface.GrassMaster installation
The surface is installed by a machine that injects the fibre into the soil. The machine has evolved over the years. The first machine used for installing a GrassMaster surface was a 2nd generation machine. It was diesel powered and had hydraulics. It weighed approx. 12 tonnes, had a speed of 15m2/hour and was steered manually. The machine was succeeded by the GrassMaster Gen-S. This machine is electrically powered and uses hydraulics to inject the yarn. It weighs 7.5 tonnes, has a speed of 20m2/hour and uses laser to guide the injection process. The latest generation machine is the Gen. 5. This machine is renowned for its silence, weighs 4.5 tonnes, has a speed of 25m2/hour, uses laser, is electrically driven, and, most importantly, no longer uses hydraulics.How much does a GrassMaster cost?
In 2022, GrassMaster charged approx. EUR 40/m2Articles on Hybrid systems

NFL introduces quality criteria for NFL fields
The NFL and the NLF Players Association (NLFPA) have agreed on a set of quality criteria pitches in the NFL league must meet from 2028.

FIFA and Saudi Fund for Development create USD 1 billion infrastructure fund
Football governing body FIFA has announced a partnership with the Saudi Fund for Development. The partnership is expected to pledge USD 1 billion to fund

New campus “not the ending point but a starting point”
French football club and Champions League winner Paris Saint-Germain has brought all their teams together in one single campus. They describe it as “a village”.

GrassMax and RED Relvados sign partnership
Portuguese grounds care company RED Relvados and stitching company GrassMax Systems have signed an exclusive partnership whereby the two companies will continue introducing hybrid surfaces

Pro League to tackle poor pitches
The Belgian Pro League has launched a drive to tackle poor stadium pitches. The league has introduced a “Sports Field Management Manual” and distributed measuring

New type of surface trialled by FIFA and UEFA
A new concept for stadium surfaces that was trialled by both FIFA and UEFA this summer, received a mixed response. The temporary, reinforced grass overlays

Groundskeeping or turf operative apprenticeship offered
Plumpton College in the UK has launched a level 2 groundskeeping or greenkeeping sports turf operative apprenticeship. The apprenticeship is open to individuals aged 16

Confusion behind 1 metre shortfall of FC Volendam field
The KNVB has revoked the certificate for the new hybrid pitch of FC Volendam. A last-minute inspection concluded that the field is 1 metre too

SIS Pitches invests in extra hybrid pitch stitching machines
SIS Pitches has invested in a fleet of 16 new hybrid pitch stitching machines. The new machines were designed and developed in-house and are more

Premier League releases pitch standards framework
The Premier League, together with testing institute STRI, have launched the Premier League Pitch Standards Framework. This resource documents the requirements of establishing and maintaining

FIFA: “World Cup pitches not good enough”
FIFA’s Global Football Development Chief, Arsène Wenger, has promised better pitches for the 2026 World Cup tournament. He has acknowledged that the quality of pitches

No difference between autonomous or traditional mowing
An Italian field trial shows that a sports field composed of 100% Kentucky bluegrass (Poa pratensis) maintains similar quality when mowed autonomously and traditionally. However,